Cisco CB250 Network Switch for Bolero
The switch should be reset to the factory default by pressing and holding the reset button on the front of the switch for approx. 15-30 seconds until all the port LEDs illuminate. The switch will take 3 minutes to be available while it re-boots.
The default IP address of the switch is: 192.168.1.254/24
Set your computer’s network interface to a static ip in the same subnet such as 192.168.1.100 with a subnet mask of 255.255.255.0.
Connect the network interface to any port of the switch, open a web browser and go to http://192.168.1.254/.
The default log-in credentials are:
Username: cisco
Password: cisco
You will be prompted to enter new login credentials, these should be:
Username admin
Password: Creat1ve
The switch will start in basic mode and should be changed to advance mode at the top of the page.
Updating the Switch with the start-up and running configurations.
Navigate to Administration >File Management > File Operations
Operation Type: Update File
Destination File type: Startup Configuration
Choose the file.
Repeat this process for the Running Configuration.
Cisco CB250 Network Switch for Odin
The following startup configuration for a Cisco CB250 network switch has been tested to work with an ODIN intercom with OMNEO and DANTE devices. As a network scales up to include multiple switches and different devices, some settings may need to be adjusted and advice should be sought from an IT professional.
The switch configuration is based on the following:
- The control VLAN is for the pc running AZ Edit programming software and ODIN control port.
- The OMNEO VLAN is for the pc running IP Edit and for the connection of OMNEO devices including ODIN.
- The Bolero VLAN is for browsing the Bolero network of Bolero antennae and Network Steam Adaptors. (NSA)
- The switch configuration can be accessed through port 1 by browsing to 192.168.1.254 using a computer with the network port in the subnet 192.168.1.xxx
The configuration is as follows:
| VLAN | Subnet | Ports | Comments |
| 1 – Management | 192.168.1.xxx | 1 | For switch configuration. |
| 50 – Control | 192.168.50.xxx | 2-4 | AZ Edit Control |
| 20 – OMNEO | DHCP | 5-20 | OMNEO Control |
| 42 – Bolero | 192.168.42.xxx | 21-24 | Bolero |
Configuration of Ports on the Switch
In addition, port 20 is configured to forward all multicast traffic and should be used to connect a PC or Mac running DANTE Virtual Soundcard e.g. Unity Intercom and unity Connect.
Setting Up ODIN
Ensure that the PC network adaptor is set with a static ip in the subnet 192.168.50.xxx (or whatever subnet the ODIN control port is in.) Connect the LC to the control VLAN, ODIN control port should also be connected to the control VLAN.
The same procedure should be carried out for the Bolero VLAN using the subnet 192.168.42.xxx
Ensure the PC network adaptor connected to the OMNEO VLAN is set to DHCP. The OMNEO control and audio IP should also be set to DHCP and the DHCP server in AZ Edit should be disabled. You may need to first give the ODIN OMNEO port a static ip, in order to make changes to the DHCP settings.
With all devices set to DHCP and in the absence of a DHCP server, the devices will discover each other and self-assign an IP address in the subnet 169.254.xxx.xxx/16. If the OMNEO devices need to be in a particular subnet, a DHCP server may be introduced or the ODIN DHCP server can be enabled and a range of addresses to issue, can be set.
The configuration file is available on Dropbox and by following the link: https://www.dropbox.com/s/yupn1ohtrxmd8gn/ODIN_startup.txt?dl=
RTS Screen Saver & Splash Screen Set Up
Here are the supported resolutions for making custom screen savers and splash screens for bigger events.
Click here to download CT branded RTS splash screens and screen savers:
https://www.dropbox.com/sh/w2nhgm0m0eivyk9/AACjh8rPAykZ6XFwpaLuTTvza?dl=0
For Digital Beltpacks DBPs:
Screen saver – min 16 x 16, max 120 pixels x 120 pixels
Splash screens must be 240 x 240 pixels, to fill the whole screen.
Supported file types are: .bmp, .gif, .jpg, .png, and .tif.
For Key Panels:
KP-4016 Screensaver – min 16 x 16, max 192 x 60
KP-5032 Screensaver – min 16 x 16, max 192 x 130
For both KP-4016 & KP-5032 splash screen – max 576 x 90
For ODIN:
Screensaver & splash screen – max 576 x 90.
If the bitmap is smaller than the full screen dimensions, the front panel centers the bitmap horizontally and vertically on the display and fills the background with the same color as the pixel in the top left corner of the splash screen.
Supported file types: .bmp, .gif, .jpg, .png, and .tif.
How to Input Groups of Channels into Wisycom Manager
This is useful if
- If your Wisycom bases have all the groups locked
- If you want to input a group of frequencies into one or several bases
- If you want to change names of bases quickly
To note: this only works with Wisycom bases with ethernet control!
Start by opening Wisycom manger. It can be downloaded here if you don’t already have it installed:
Next connect your base(s) either directly to your laptop or via a flattened network switch.
Open the network settings (in the top bar) and make sure the connection is set to ethernet.
Your base will show up in the ‘Discover devices’ box in the bottom right. If it doesn’t show up here first time, open the network settings and close them again. This refreshes the discovery list. If that doesn’t work, restart Wisycom manager.
Once your device(s) has appeared you should be able to see the IP address it is set to. Put your laptop in the same range.
If it still isn’t showing up here, use the bases to find the IP address.
On the screen on the front of the base go to menu, scroll to the bottom and click on info. Set your laptop IP to be in the range and continue following these steps.
Go to the network interface section in Wisycom manager to check the IP has changed (sometimes it does not refresh properly, so please check this!)
Opening the network interface selection refreshes the devices discovery, the bases should appear and fill in their details.
This image shows a base with its information populated
Now change the IP of the base. To change it, press the little edit button next to the IP address.
This ethernet setting box will appear. Set your IP address. If you have a rack of bases, make sure each base is in the same IP range but not on the same IP.
Remember once you have done this you will need to change your laptop IP to this new range.
Remember to open network interfaces in Wisycom manager and check it has successfully changed in there as well.
Once it has connected successfully press the connect device button (the little up arrow). This will move the base up into the active devices.
Once in the active devices section you can access the main settings for the base. Press the small edit button (pencil button) on the base you wish to change the settings for.
A settings page like this one will open. This page slightly changes with the various bases we own. But the key information stays the same.
Now change your bases names.
Open the channel memory bank. Press the view button next to channels memory.
Now press the big edit (pencil button) in the top left. This will expand the menu along the top.
As our bases don’t get wiped after every gig, there will be a lot of random frequencies that aren’t relevant. To clear them all at once, highlight all the frequencies, right click and select Edit Sel. channel(s).
e
This menu will open. I usually then change the frequency box to 470000 for 470Mhz and also make sure Hidden and Locked are NOT selected. If these are the channels will be locked or hidden and not change properly.
Press apply and the highlighted frequencies will all change to 470Mhz
Then reset all the group names and descriptions. To do highlight all the groups and descriptions, right click and press Edit Sel. group(s)
This similar menu will open. Delete everything in the Name and Description boxes and make sure Hidden and Locked are NOT selected.
Press Apply and all the group names and descriptions should be cleared.
Now we start to look at filling in the relevant information for our job.
Fill in the frequencies given you to by Ofcom or the client.
Here is what it should look like after you have filled in your information.
Press the arrow pointing to the right. This sends the changes to base station.
Wait till the blue bar gets to 100%, then your frequencies will be in the base.
Whilst you are on this page, save the frequency bank file, so you can copy it into your other bases or future bases.
Select the frequencies you have input. If the front of the base doesn’t update, turn it off and on again. That’ll push a hard refresh to the base frequencies.
To load the file you made into more bases press the Load Frequencies button in the top left.
This menu will appear. Press the Select a file button and choose the frequency bank file you made earlier. You need to select the file for each base you wish to copy the frequencies to.
The bases you have input a file for will automatically tick themselves under devices. If not make sure they are ticked and then press the play button. This will input the channels/frequencies into the bases.
Radio Programming Helpful Tips
Before you start programming ask yourself:
-
Has Alex Bond done this for you? (Alex has a suite of default files that may not need editing at all!)
-
Is there something else similar you can adapt? (It’s much easier to modify an existing Radio file than it is to create something from scratch.
-
Are you being a lazy radio engineer? (Try to stay away from the very low PL codes. NEP Standard radio file uses 67Hz as their simplex PL.
-
Have you saved a new file when you’ve finished making changes? (This means you have a very quick fix when you accidentally break the system!)
If you need to create your own radio file, please click the button below to be taken to a post with more information.
Tips for Programming TAIT Analogue CPS
- Try to use known good files where possible. This keeps all preset defaults the same.
- Power varies between 25W & 40W. Make sure you plan how that power goes through the system.
- If you’re mixing the H5 & H6 bands, you’ll need to change the band in the specification tab.
- Depending on the environment you may want to change the Squelch sensitivity. Most of the time we use country Squelch but in busy environments you may want to switch to City or hard squelch.
If you need more information on programming radio files, please see the following KB article:


Leave a Reply